| Frequency range | 170 MHz to 250 MHz |
| Power supply | 3 x 400 V AC ±15 %, three-phase operation; 47 Hz to 63 Hz |
| Max. installation altitude | 2000 m above sea level (>2000 m on request) |
| Operating temperature range | +1 °C to +45 °C |
| Permissible relative humidity | 95 , without condensation |
| Dimensions (W × H × D) | 600 mm × 2000 mm × 800 mm |
| RF connector | 1 5/8 EIA |
| Synchronization |
| Reference frequency | 10 MHz, 0.1 V to 5 V (pp) or TTL, BNC |
| Reference pulse | 1 Hz, TTL, BNC |
| Local and remote control |
| Local control |
| Color display and keys | front-panel operation via graphical user interface (GUI) |
| RJ-45 | PC operation via standard Web browser |
| Remote control |
| RJ-45 | IEC 864-2 via Ethernet, standard |
| RJ-45 | network management interface (Web server and/or SNMP agent), optional |
| Parallel interface | fl oating contacts for messages and commands, optional |
| Bit bus | bus interface, meets IEC 864-2, optional |